Go target program – Epson S1C62 Family User Manual
Page 176
Advertising

Format
ICE CONTROL SOFTWARE ICS62XX
VIII-62
EPSON
S1C62 FAMILY
DEVELOPMENT TOOL REFERENCE MANUAL
G
GO TARGET PROGRAM
#G
#G,
<address >
#G,R
#OTF
...
On-the-fly set command
* ON THE FLY ON *
These settings
#BE
...
Break enable set command
are set at power
on; default is
* BREAK ENABLE MODE *
command input
#BT
...
Break stop mode set command
* BREAK STOP MODE *
#G,R
...
Target and evaluation board is reset; run starts from
reset address (0100)
*PC=xxxx
...
PC display is cyclic
*EMULATION END STATUS = BREAK HIT
...
(A)
*PC=01FF A=5 B=0 X=70 Y=05 F=..ZC SP=20
...
(B)
*RUN TIME=100mS
...
(C)
(A) Break displayed through break condition (BA condition set at 01FE)
(B) F is expresses reset bit and (.) bit as English letter
(C) Run time is 100mS
#
Examples