1.

Prepare to connect neutral ground

wire and neutral wire

E

B

A

2.

Connect neutral ground wire and

neutral wire

C

E

B

Remove center terminal block screw (B). Remove neutral

ground wire (E) from green external ground conductor screw (A).

Connect neutral ground wire (E) and neutral wire (white or

center) (C) of power supply cord under center terminal block

screw (B). Tighten screw.

3.

Connect ground wire

F

A

Connect ground wire (F) (green or bare) of power supply cord

under green external ground conductor screw (A). Tighten

screw.

3-wire receptacle

(NEMA type 10-30R)

3 prong plug

Spade terminals with

upturned ends

Ring terminals

4.

Connect remaining wires

1.

Remove center screw

B

Connect remaining wires under outer terminal block screws.

Tighten screws. Finally, reinsert tab of terminal block cover

into slot of dryer rear panel. Secure cover with hold-down

screw. Now, go to “Connect Outlet Hose.”

Remove center terminal block screw (B).

3-Wire Power Supply Cord Connection

Use where local codes permit connecting cabinet-ground

conductor to neutral wire.