INSTALLATION INSTRUCTIONS

Requirements for alcove or closet installation

!

WARNING!

Explosion Hazard

Keep flammable materials and vapors, such as gasoline, away from dryer.

Place dryer at least 18" (46cm) above the floor for a garage installation.

Failure to do so can result in death, explosion, or fire.

Minimum clearance between dryer cabinet and adjacent walls or other surfaces is:

3/4” (20mm) sides, front, and top
1” (25.4mm) rear

Consideration must be given to provide adequate clearance for installation and service.

Closet doors must be louvered or otherwise ventilated and have at least
60 square inches (387cm

2

) of open area. If the closet contains both a washer and a

dryer, doors must contain a minimum of 120 square inches (774cm

2

) of open area.

Minimum clearance other than alcove or closet installation

Minimum clearance to combustible surfaces and for air opening are:

3/4” (20mm) sides and top
1” (25.4mm) rear

Consideration must be given to provide adequate clearance for installation and service.

Mobile or manufactured home installation

Installation MUST conform to the MANUFACTURED HOME CONSTRUCTION AND
SAFETY STANDARD, TITLE 24, PART 3280 or STANDARD FOR MOBILE HOMES
CAN/CSA-Z240 MH, or, when such standards are not applicable, with AMERICAN
NATIONAL STANDARD FOR MOBILE HOME, ANSI/NFPA NO. 501B.

Provide an opening with a free area of at least 25 square inches (161cm

2

)

for introduction

of outside air into the dryer room.

See the sections for electrical connection information.

Bathroom or bedroom installation

The installation must conform with local codes or, in the absence of local codes, with
the NATIONAL ELECTRICAL CODE, ANSI/NFPA NO. 70 (for electric dryers).