Important, Installation instructions – Fisher & Paykel 24 Inch Condensing Dryer Install Guide User Manual

Page 16

Advertising
background image

14

INSTALLATION INSTRUCTIONS

Connecting dryer using 3-wire connection

If required, by local code, install external ground (not provided) to grounded metal,
cold water pipe, or other established ground determined by a qualified electrician.

L1 N L2

Cover

Ground strap

3/4” Strain relief
and bracket

3 #10 AWG minimum copper conductors or 120/240V 30A power supply cord kit marked for use
with dryers and provided with closed loop or spade terminals with upturned ends (not supplied)

3-wire connection

●

●

Not for use in Canada.

●

●

DO NOT use for Mobile Home Installations.

●

●

NOT for use on new construction.

●

●

NOT for use on recreational vehicles.

●

●

NOT for use in areas where local codes prohibit grounding through the
neutral conduction.

1

Turn off the circuit breaker(s) (30 amp) or remove the dryer’s circuit fuse at the
electrical box.

2

Be sure the dryer cord is unplugged from the wall receptacle.

3

Remove the power cord cover located at the upper back.

4

Install 3/4 in. UL-recognized strain relief to power cord entry hole.
Bring power cord through strain relief and bracket.

5

Connect power cord as follows:

A. Connect the 2 hot lines to the outer screws of the terminal block (marked L1 and L2).
B. Connect the neutral (white) line to the center of the terminal block (marked N).

6

Be sure ground strap is connected to green ground screw on cabinet rear.
Tighten all terminal block screws (3) securely.

7

Properly secure power cord to strain relief and bracket.

8

Reinstall the cover.

IMPORTANT!

Never leave the cover off of the terminal block.