Gas conversion – Bertazzoni Master Series 36 Inch Gas Rangetop Installation, Use & Care Manual User Manual

Page 16

Advertising
background image

16

GAS CONVERSION

Warning!

Before carrying out this operation, disconnect the
appliance from gas and electricity.
Gas conversion shall be conducted by a fac-
tory-trained professional.
Call the customer service hotline to identify a fac-
tory-trained professional near your home.

The gas conversion procedure for this rangetop
includes 4 steps:

• Pressure

regulator

• Surface

burners

• Visual checks prior to closure of oven bottom

panel

• Adjustment of minimum setting

The conversion is not completed if all 4 steps have
not been concluded properly.

Before performing the gas conversion, locate the
package containing the replacement nozzle ship-
ped with every range.

IMPORTANT:

Each nozzle has a number indica-

ting its

fl

ow diameter printed on the body. Consult

the table number 1 for matching nozzles to bur-
ners.
Save the nozzles removed from the rangetop for
future use.

Step 1: pressure regulator

The pressure regulator supplied with the applian-
ce is a convertible type pressure regulator for use
with Natural Gas at a nominal outlet pressure of
4” iwc or LP gas at a nominal outlet pressure of
10”iwc. and it is pre-arranged from the factory to
operate with one of these gas/pressure as indica-
ted in the labels a

xed on the appliance, package

and Instruction booklet.
To convert the regulator for use with the other gas:
Unscrew by hand the upper cap of the regula-
tor, remove the white plastic attachment from the
cap, reverse its direction and screw it again

fi

rm-

ly against the cap. The white plastic attachment
has arrows indicating the position for natural gas
(NAT) and LP gas (LP).
Screw by hand the metal cap in the original posi-
tion on the regulator.

Step 2: surface burners

To replace the nozzles of the surface burners, lift
up the burners and unscrew the nozzles shipped
with the rangetop using a 7 mm (sochet wrench).
Replace nozzles using the conversion set sup-
plied with the rangetop or by a Bertazzoni authori-
zed parts warehouse. Each nozzle has a number
indicating its

fl

ow diameter printed on the body.

Consult the table number 1 and matching nozzles
to burners.

/ Gas conversion

LP

NAT

Advertising