Installation – Enviro Kodiak 1700 Freestanding User Manual

Page 29

Advertising
background image

29

Installation

The flue collar is removable for installations

into fireplaces with low openings.

a) Remove the first two (2) front secondary

air tube and ceramic baffles, if installed

(see C

ERAMIC

B

AFFLE

I

NSTALLATION

).

b) Unscrew the nut on top of the inside

of the firebox, using a

9

/

16

” wrench or

socket (see Figure 31). The flue plate

clamp will slide off the hook/clamp.

c) Pull the hook/bolt and the removable

flue collar off the top of the unit.

Figure 32: Attaching removable flue.

Figure 33: Leveling leg.

Nut

Hook/bolt

Flue plate clamp

d) Attach the flue collar to the venting pipe using

sheet metal screws.

e) Push the unit into place while trying to keep the

collar attached to venting close to the opening

on the top of the unit.

f) Using the hook/bolt, grab the flue collar by the

rod through the center and pull it into place (see

Figure 32).

g) Slide the flue plate clamp over the end of the

hook/bolt and screw the nut back on to the

hook/bolt.

h) Re-install ceramic baffles and the first two (2)

front secondary air tube (see C

ERAMIC

B

AFFLE

I

NSTALLATION

).

3. There are two (2) leveling legs (shown in Figure 33),

one on each side, at the back of the unit. Adjust the

legs using a

9

/

16

” wrench to ensure the unit is stable.

Figure 31: Attaching removable flue.

4. Screw or nail the metal plate provided by the manufacturer to the

inside of the fireplace.
METAL TAG: “THIS FIREPLACE HAS BEEN ALTERED TO ACCOMMODATE

A FIREPLACE INSERT AND SHOULD BE INSPECTED BY A QUALIFIED

PERSON PRIOR TO THE RE-USE AS A CONVENTIONAL FIREPLACE.”

Advertising