Elo TouchSystems ET1529L User Manual

Page 120

Advertising
background image

Section 4. USB Communications

19

TERMINATION_CHAR PROPERTY

Property ID:

5

Property Type:

Byte

Length: 1

byte

Get Property:

Yes

Set Property:

Yes

Default Value:

0D (hex) (carriage return)

Description:

This property is defined as follows:

mod

c c c c c c c

mod 0 – Send c after card data

1 – Send c after each track

c

1-127 – 7 bit ASCII char code

0 – send nothing


This property is stored in non-volatile EEPROM memory so it will not change when the unit is
power cycled. When this property is changed, the unit must be power cycled to have these
changes take effect. If a value other than the default value is desired, it can be set by the factory
upon request.

SS_TK2_7BITS PROPERTY

Property ID:

6

Property Type:

Byte

Length: 1

byte

Get Property:

Yes

Set Property:

Yes

Default Value:

40 (hex) ‘@’

Description:

This character is sent as the track 2 start sentinel for cards that have track 2
encoded in 7 bits per character format. If the value is 0 no character is sent. If
the value is in the range 1 – 127 then the equivalent ASCII character will be
sent.


This property is stored in non-volatile EEPROM memory so it will not change when the unit is
power cycled. When this property is changed, the unit must be power cycled to have these
changes take effect. If a value other than the default value is desired, it can be set by the factory
upon request.

Advertising