5000 Series Ultra Duty

2 Terminals

Metri-Pack Integral Connector

Pressure Switches

(See Note 1)

Contact Factory Circuitry Screw

Blade

Contact Factory Circuitry Part #

Setting

Set At

Part #

Part #

Setting

Set At

N.O.

83298

83313

N.O.

83328

10-35 PSI

20 PSI

N.C.

83299

83314

10-30 PSI

20 PSI

N.C.

83329

±4 psi

± 4 psi

DC*

83300

83315

DC*

83330

N.O.

83301

83316

N.O.

83331

35-75 PSI

60 PSI

N.C.

83302

83317

30-65 PSI

45 PSI

N.C.

83332

± 6 psi

± 5 psi

DC*

83303

83318

DC*

83333

N.O.

83304

83319

85 PSI

N.O.

83334

75-150 PSI

100 PSI

N.C.

83305

83320

65-125 PSI

N.C.

83335

±10 psi

± 7 psi

DC*

83306

83321

DC*

83336

N.O.

83307

83322

N.O.

83337


150-250 PSI 200 PSI

N.C.

83308

83323

125-200 PSI 165 PSI

N.C.

83338

± 15 psi

± 10 psi

DC*

83309

83324

DC*

83339

N.O.

83310

83325

N.O.

83340


250-400 PSI 300 PSI

N.C.

83311

83326

200-400 PSI 300 PSI

N.C.

83341

± 20 psi

± 15 psi

DC*

83312

83327

DC*

83342

Honeywell Sensing and Control has designed a high pressure/low set point
pressure switch for applications that see sudden pressure spikes and high
system pressures that can result in early switch failures. This series has been
strengthened to prevent cracking of the base with plated steel and screw
machined components in a 3-piece design. Modifications to the effective
area of the pressure cavity and size of the diaphragm button and diaphragm
o-ring are what makes the switch capable of handling sudden pressure
transients and high system pressures that are common in applications such as
braking, transmission and hydraulic systems.
The switch’s physical appearance is similar to our 5000 Series switches with a
height of only 2.3” (approx) and a diameter of 1.47”. In comparison to our
5000 Series Switch the burst rating has significantly increased from 1250 psi
to over 4000 psi on the new design.

Specifications

Type: Direct action blade contact
Contacts: Silver alloy, gold plated
Set Point Range: 10-400 PSI
Operating Pressure: 500 PSI
Proof Pressure: 2000 PSI
Burst Pressure: 4000 PSI
Base: Plated Steel — Screw Machined
3-piece construction
Diaphragm: Polymide Film
Connector: 1/8-27 NPT Male Thread
Temperature Range: -40°F to +250°F
Terminals: #8-32 screws, 1/4” blade,
280 Series Metripack
Circuitry: SPST-N.O., N.C., SPDT
Cover: Glass Reinforced Polyester
Options: Base connector sizes, wire
leads, N.O./N.O. dual circuit and
N.C./N.C. dual circuit.

Ratings:

Resistive: 15 AMP-

6 VDC

8 AMP- 12 VDC

4 AMP- 24 VDC

Inductive:

1 AMP- 120 VAC

0.5 AMP- 240 VAC

Set Points from 10-400 psi
5000 Series

Ultra Duty Pressure Switch

3

10-35 PSI
35-75 PSI

75-150 PSI

150-250 PSI
250-400 PSI

Contact Setting

Approximate Dead Band

Standard Switches

Dead Band

15-25 PSI
25-35 PSI
40-60 PSI
50-70 PSI

80-100 PSI

Metri-Pack Switches

10-30 PSI
30-65 PSI

65-125 PSI

125-200 PSI
200-400 PSI

20-35 PSI
35-55 PSI
60-85 PSI

85-115 PSI

150-200 PSI

Note 1: Mating connector for N.O. and N.C. is

Packard Part# 15300027; Mating connector for
DC is Packard Part# 12034147.

DC*- The N.C. is the reference circuit for the

DC Switch; the N.O. circuit is not adjusted. The
approximate dead band between the N.C. and
N.O. circuit is shown in the charts. For applications
requiring the N.O. circuit as the reference circuit,
the N.C. circuit is not adjusted.