D. frame the fireplace, C. sidewalls/surrounds – Hearth and Home Technologies BAY-40 User Manual

Page 20

Advertising
background image

20

47-1/8 in.

(1197 mm)

Header Height

12 in. max.

(305 mm)

2 in. (51 mm) minimum air space

clearance to enclosure

BAY-40

2 in. (51 mm) minimum air space

clearance to enclosure

12 in. max.

(305 mm)

PIER-40

47-1/8 in. (1197 mm)

Header Height

Mantel

Mantel

11.92 in.

[303 mm]

FLUSH
FRONT

40 in.

[1016 mm]

36 in.

[914 mm]

(fireplace opening)

12 in.

[305 mm]

50° angle

9 3/4 in.

[248 mm]

4 in.

[102 mm]

BRICK

FRONT

40 in.

[1016 mm]

36 in.

[914 mm]

(fireplace opening

12 in.

[305 mm]

39° angle

D. Frame the Fireplace

Figure 6.4 shows typical framing using combustible materials (2x4 lumber shown).

• Observe all required air space clearances to combustible materials as shown in Figure 6.1 & 6.2.
• Framing across the top of fi replace must be above top standoffs.

Figure 6.4 Framing the Fireplace

C. Sidewalls/Surrounds

• Adjacent combustible sidewalls must be located a minimum of 12 in. (305 mm) from the fi replace opening.
• Combustible and noncombustible mantel legs, surrounds and stub walls may be constructed within the gridded area,

Figure 6.3.

Figure 6.3 Mantel Leg or Wall Projections

Heat & Glo • BAY-40, PIER-40 • 34977 • Rev W • 11/08