Caution, Clearing blockages, Lubrication – Hoover 56511A46 User Manual

Page 27: Checking under bottom plate, Checking airflow path

Advertising
background image

14

ClearinG bloCkaGes

4.17

b

Checking under bottom plate

4. Turn cleaner OFF and unplug.
5. Remove bottom plate, belt and agitator (see “BELT:

How to Replace section” section).

Look into opening (D) for blockages and remove.
6. Remove agitator shield (see Fig. 4-10) and remove any

loose debris which may have accumulated under it.

4.18

d

CAUTION

!

!

To reduce the risk of injury from moving parts,

unplug vacuum before servicing.

Low suction or pick up may be due to a blockage in the

system. Refer to the following steps to check for

blockages continuing with each step until the blockage is

found:
1. Check fullness of filter bag; change if needed.

Checking airflow path

2. Plug cleaner in and turn ON. Check for suction at end

of hose (A).

a. If there is suction, continue with step 3.

b. If there is no suction, check for blockage in

hose and dirt tube as follows:

1) Disconnect hose from dirt duct (C) by

reversing procedure for “ATTACH HOSE”.

2) Clear out hose.

3) Look into (C) and remove blockage.

3. Check connection at hose tube (B); remove any block-

age.

lubriCation

The motor is equipped with bearings that contain sufficient lubrication for the life of the motor. The addition of lubricant

could cause damage. Therefore, do not add lubricant to motor bearings.
The agitator is equipped with two ball bearings that should be lubricated periodically by an Authorized Hoover Warranty

Service Dealer (Depot).

Advertising