Send diagnostic 1dh, Send diagnostic 1dh 14, Pre-execution checks – HP C737990900 User Manual

Page 145: Command descriptor block: cdb fields

Advertising
background image

Commands 145

Co

m

m

an

ds

SEND DIAGNOSTIC

1Dh

S

END DIAGNOSTIC

tells the drive to perform either its standard self-test, or

diagnostics specified in the parameter list on itself. The parameter list is

transferred to the drive in a series of data-out phases; each 8-byte data-out

phase specifies a diagnostic to be performed by the drive. It is not an error to

set Self-Test = 0 and to have a zero-length parameter list.
The test results can be retrieved with the

RECEIVE DIAGNOSTIC RESULTS

command.

Pre-Execution Checks:

■

If Self-Test = 0, the UntOffl bit must be set, otherwise

CHECK CONDITION

is

reported. Sense data will be as described in Illegal Field Checks.

■

If Self-Test = 1, the Parameter List Length field must be zero. Otherwise

CHECK CONDITION

is reported. Sense data will be as described in Illegal

Field Checks.

■

It is not an error to set Self-Test = 0 and to have a zero-length parameter

list.

Command Descriptor Block:

CDB Fields:

Illegal Field

Reservation

Deferred Error

Unit Attention

7

6

5

4

3

2

1

0

0

Operation Code (1Dh)

1

Reserved (0)

PF (1)

Rsvd(0)

Self-Test

DevOffL(0)

UnitOffL

2

Reserved (0)

3

(MSB)

Parameter List Length

4

(LSB)

5

Control

PF

Page Format.

Specifies that the accompanying data follows the SCSI-3 Diagnostic Page format.

It must be set to 1.