5.

Connect the air supply to the tool at the Quick Connector (83). Set the regulator

at the recommended 70 to 120 operating PSI. Do not exceed the maximum

120 PSI.

6.

Test the tool by depressing the Safety (50A) against the workpiece without

pulling the Trigger (36). The tool must not cycle (fire). If it cycles (fires), stop

immediately and have it repaired by a qualified service technician.

7.

Hold the tool away or off the workpiece. The Safety (50A) of the tool should

return to its original position. Squeeze the Trigger (36). The tool should not

cycle (fire). If the tool cycles (fires), stop immediately and have it repaired by a

qualified service technician.

8.

Depress the Safety (50A) against the workpiece and squeeze the Trigger (36).

The tool must cycle (fire) only once. Release the Trigger and squeeze it

again. The tool must not cycle (fire). With the Trigger held, carefully lift

the Nailer and press it against the workpiece again. The tool must not cycle

(fire). If it fails to perform in the manner explained in bold, have it repaired by a

qualified service technician.

LOADING BRADS

WARNING: Always wear ANSI approved impact safety goggles when

reloading or performing any other maintenance on this tool. Other

people in the work area must also wear ANSI approved impact safety

goggles.

1.

Slide the Pusher (63) back until it locks in place.

2.

Place a full clip of the desired size Brads (3/4” to 2”) in the Magazine Assembly

(70). Up to 100 Brads may be loaded in the Magazine.

Pusher (63)

Magazine

Assembly (70)