I. air shutter setting, G. fixed glass assembly, H. install the mesh – Heat & Glo Fireplace HEAT & GLO Escape-42DV User Manual

Page 52

Advertising
background image

Heat & Glo • Escape-42DV • 2052-900 Rev. Y • 11/11

52

I. Air Shutter Setting

Air shutter settings should be adjusted by a qualifi ed ser-

vice technician at the time of installation. The air shutter

is set at the factory for minimum vertical vent run. Adjust

air shutter for longer vertical runs.
NOTICE: If sooting occurs, provide more air by opening

the air shutter.

Figure 14.1 Fixed Glass Assembly

G. Fixed Glass Assembly

WARNING! Risk of Asphyxiation! Handle fi xed glass

assembly with care. Inspect the gasket to ensure it is

undamaged and inspect the glass for cracks, chips or

scratches.
DO NOT strike, slam or scratch glass.
DO NOT operate fi replace with glass removed, cracked,

broken or scratched.

Replace as a complete assembly.

Removing Fixed Glass Assembly

• Remove the ash lip that is located in front of the glass.
• Remove the side panels located in front of the glass.
• Remove the pull mesh fi rescreen by unhooking from the

fi replace.

• Pull and release the six glass latches (3 per side) located

on the sides of the glass frame.

• Grasping the upper lip with one hand and the lower lip

with the other, pull the bottom of the glass out fi rst. Guide

the bottom while letting the top drop down under the top
of the opening (see Figure 14.1).

Replacing Fixed Glass Assembly

• Replace the glass door on the appliance. Pull out and

latch the six glass assembly latches into the groove on

the glass frame.

H. Install the Mesh

The pull-type fi rescreen hangs on the three hanger brack-

ets located above the glass.

Air Shutter Settings

NG

LP

ESCAPE42-DV

3/8 in.

N/A

ESCAPE42-DVLP

N/A

11/16 in.

GLASS

CLIP

UPPER

LIP

Advertising
This manual is related to the following products: