Troubleshooting Tips

Presented below is a table showing general guidelines for repairing units with specific failure
symptoms. The order of likely causes is based upon data gathered by HP from analysis of failed
modules. The suggested order of investigation is not mandatory but reflects the priority HP
would currently place on looking for the root cause.

Swapping of easily replaced modules with known good reference modules is the ideal way to
isolate the cause down to the module level. It is rare for more than one module to be
responsible for the same failure symptom. Therefore, replacement of more than one module for
a particular symptom should be the exception rather than the normal expectation.

After replacing modules, it is normal for some units to end up in a confused state and lock up
when ac power is applied. If this occurs, the reset button should be pressed to bring the
computer to a known state. If the unit still locks up or continues to lock up each time ac power is
applied, the unit needs additional analysis.

Table 14 - OmniBook Troubleshooting Tips

Symptom

Call Center

Likely Cause
(in order)

Comments

Battery

Won’t run on
battery — no bars
in battery icon

•

Try known good

battery in suspect unit

•

Try suspect battery in

known good unit

•

Send in for repair

•

Battery

•

PT-586

Battery won’t
charge — light
blinks

•

Try known good

battery

•

Send in for repair

•

Battery

Battery won’t
charge — no
charge indicators

•

Try known good

battery in suspect unit

•

Try suspect battery in

known good unit

•

Send in for repair

•

PT-586

•

Possible solder problem

on RT1

Hard Disk Drive

HDD doesn’t spin
at all

•

Verify known good

power source

•

Reseat HDD

•

Send in for repair

•

PT-586

•

HDD

•

HDD flex

cable

•

HDD plastic kit

•

If the HDD plastic kit is

bent or otherwise
misshapen, the HDD may
not function properly.

Display

Dark display — no
light

•

Ensure

contrast/brightness
button is installed
properly

•

Adjust

contrast/brightness

•

Send in for repair

•

Broken

backlight tube

•

Replace display

Video problems —
appears horizontal
hold is out

•

Send in for repair

•

Display

connector not
seated

•

Lift up icon assy — push

down on left display
connector.

Advertising