HP 2000 User Manual

Page 60

Advertising
background image

58

Symptom

Call Center

Likely Cause
(in order)

Comments

correctly.

Keyboard

Keyboard errors —
2 characters on a
keystroke instead
of one

•

Send in for repair

•

PT-586

•

PT-DC

•

Keyboard

•

Damaged U10

•

Shorted pins on

connectors

Keyboard errors —
no response from
key(s)

•

Send in for repair

•

PT-DC

•

PT-586

•

Keyboard

•

Possible bad connector

solder joints

Keyboard doesn’t
respond, audio
slow, battery
problems

•

Send in for repair

•

PT-586

•

Damaged U10

Unit Hangs or
Won’t Boot up

Won’t boot up &
no display

•

Verify known good

power source

•

Push reset button

•

Try pulling RAM

module and re-
inserting

•

Send in for repair

•

PT-CPU

•

RAM module

•

PT-DC

•

PT-586

•

PT-ICON

•

Swap with reference CPU

to check. Replace
original CPU if not fixed.

•

Make sure RAM is seated

properly — remove and
re-install to check.

Unit hangs at
Win95 screen
during boot

•

Eliminate any s/w

configuration conflicts

•

Send in for repair

•

PT-586

•

Possible burnt R92 hangs

up audio IC

Unit locks up after
2-3 minutes

•

Run BIOS upgrade

program

•

Send in for repair

•

PT-ICON

•

Corrupt EEPROM — run

BIOS upgrade

Unit goes into
suspend after
“Bridge controller”
message, won’t
resume

•

Send in for repair

•

PT-586

•

Damaged U10

TrackPoint/Cursor

Cursor pointer
drifts slightly.

•

It is normal for the

cursor to drift slightly
as the circuit does

•

Keyboard and

palmrest.

•

Be sure keyboards are

tested with the correct
palmrest. The latest

Cursor pointer
“flying” or drifting
excessively.

a self calibrate every
once in a while

•

Send in for repair.

•

Mismatched

palmrest and
keyboard pair

TrackPoint sensor (CTS)
must match up with a
CTS palmrest.
Mismatched keyboards
and palmrests result in
the cursor moving

Cursor moves in
the opposite
direction of
TrackPoint
movement

in the opposite direction

of intended movement.

•

Refer to Service Note

5500-04.

Miscellaneous

Loses time

•

Plug AC adapter into

unit and let it charge
for at least 24 hours.

•

PT-586 Philips

IC

•

Refer to Service Note

5500-01 for IC problem

Advertising