Torch and work cable connections, 5. torch and work cable connections – Hobart Welding Products AIRFORCE OM-230 455D User Manual

Page 28

Advertising
background image

.

A complete Parts List is available at www.HobartWelders.com

OM-230 455 Page 24

6-5.

Torch And Work Cable Connections

Y

Turn Off power source, and
disconnect input power.

If torch or work cable needs to be
removed or replaced, proceed as
follows:

1

Power Source

Remove wrapper from unit.

Torch Connections

Remove existing torch cable from
unit.

2

Strain Relief

3

Torch Cable

Insert strain relief on end of cable
through front panel opening. Slide
strain relief nut onto torch cable, but
do not tighten.

4

Air Line Connector

Install air line connector onto
compressor fitting.

5

Plug PLG4/Receptacle RC4

Connect PLG4 to receptacle RC4
on circuit board PC1.

6

Female And Male Friction
Terminal RC1/ELECTRODE

Connect female friction terminal
on end of black lead to
RC1/ELECTRODE.

7

Female And Male Friction
Terminal RC2/TIP

Connect female friction terminal on
end of red lead to RC2/TIP.

Tighten strain relief nut.

Tighten strain relief around cable.

Work Cable Connections

Remove existing work cable from
unit.

8

Strain Relief

.

Be sure to allow some work
cable slack inside the unit.

Insert strain relief on end of cable
through front panel opening. Slide
strain relief nut onto work cable and
secure strain relief to front panel.

9

Work Lead Male Friction
Terminal

Connect work clamp lead to male
friction terminal labeled WORK on
circuit board PC1.

Reinstall wrapper.

Tools Needed:

8

Ref. 804 852-B / 804 887-A

2

1

3

4

6

2

5/16 in

5

7

9

5

6

7

Advertising