CHECKING REMOTE AND INDOOR

TEMPERATURES

The remote temperature information line is located on

the top of the main unit’s display.

The wave icon is located above the remote channel

number and indicates the reception status from the

remote sensor.

There are three remote status types:

The indoor temperature with the icon IN is located

below the remote temperature information line.

NOTE: If the indoor or remote temperature goes above

or below operating range stated in specifications, the

main unit’s display will show dashes “- - -

MAXIMUM AND MINIMUM READINGS

The maximum and minimum record of the indoor and

remote temperatures will be automatically stored in the

memory of the main unit (receiver).

To display the minimum, maximum or the current

reading press MEMory button.

If no button is pressed for the next 15 seconds, the unit

will return to the current temperature display.

To clear the memory, press and hold MEMory button

for two seconds and all previously stored readings will

be erased.

NOTE: Batteries in the outdoor remote sensors may

have reduced voltage supply and a shorter effective

range at temperatures below freezing. We

recommend using lithium batteries below 32°F

(0°C).

BATTERY INSTALLATION

REMOTE SENSOR
NOTE: Install the batteries; select the channel and

temperature in C° or F° before mounting the remote

sensor.

• Remove the screws from the battery compartment

with a small Phillips screwdriver.

• Select the desired channel. The switch is located in

the battery compartment. Channel 1 is the default

setting and typically selected if only one remote

sensor is being used.

• Install 2 “AA” size alkaline batteries (not included)

matching the polarities shown in the battery

compartment.

• Replace the battery compartment door and secure the

screws.

• Secure remote sensor in the desired location.

MAIN UNIT

• Open the battery compartment door.

• Install 2 batteries (UM-3 or “AA” size 1.5V) matching

the polarity as shown in the battery compartment.

• Replace the battery compartment door.

BEFORE YOU BEGIN

• The remote sensor can be placed indoors or

outdoors, the main unit must be placed indoors.

• We recommend using alkaline batteries for the

remote sensor and main unit when temperatures are

above 32°F (0°C). We recommend using AA lithium

batteries for the remote sensor when temperatures

are below 32°F (0°C).

• Avoid using rechargeable batteries. (Rechargeable

batteries cannot maintain correct power requirements).

• Insert batteries before first use, matching the polarity

in the battery compartment.

ALWAYS install batteries in the remote sensor

before the main unit.

• Press RESET after each battery change with a paper

clip or similar tool.

• During an initial setup, place the main unit as close

as possible to the remote sensor.

• After reception is established (the remote temperature

will appear on the main unit’s display), position the

remote sensor and the main unit within the effective

transmission range of 100 feet (30 meters).

NOTE:

1. Avoid setting manually the time and date on the main

unit before the remote temperature is displayed.

2. The effective operating range may be influenced by

the surrounding building materials and how the receiver

and transmitter are positioned.

3. Place the remote sensor so that it faces the main unit

(receiver), minimizing obstructions such as doors,

walls, and furniture.

4. Though the remote sensors are weather-resistant,

they should be placed away from direct sunlight, rain

or snow.

LOW BATTERY WARNING

A low-battery indicator [ ] will appear on the indoor

or remote temperature reading line of the main unit

warning that the corresponding batteries need

replacement.

TABLE STAND

The main unit has a removable table stand that supports

it on the flat surface. Attach table stand to the bottom of

the main unit in the slots provided. The unit can also be

mounted on the wall using the recessed screw hole. The

table stand must be removed prior to mounting.

GETTING STARTED

After batteries are installed; the remote sensor will

transmit temperature readings at 45 second intervals.

The main unit may take up to two minutes to receive

the initial readings. Upon successful reception, remote

temperature will appear on the top line of the main

unit’s display. The main unit will automatically update

readings at 45-second intervals.

If no signals received from the remote sensor within

two minutes, dashes [- - -] will be displayed. Press and

hold DOWN ( ) button on the main unit for two

seconds to initiate another signal search.

The unit is in searching mode.

Temperature readings

securely registered.

No signals detected.

- - -