OM-928 Page 16

6-2. Trouble Light And Checking Shield Cup Shutdown System

If certain problems occur, the

trouble light comes on, and output

stops.
1

Trouble Light
a

Lights if shield cup is loose.

Turn power Off, and check

shield cup connection

(see Item 2 below). Power

must be reset whenever

the cup shutdown is

activated.
Check shield cup

shutdown system once a

week.

b

Lights if power source

overheats (see Sections

4-3 and 4-5).

c

Lights if input power is not

within specification (93 to

137 vac). Power must be

reset whenever the input

voltage shutdown is

activated.

2

Torch Shield Cup

Turn Power On and loosen shield

cup. If shutdown system works

properly, trouble light comes on. If

not, turn power Off and check for

loose shield cup.

Check consumables (see Sections

6-4 and Parts List).
If system works properly, retighten

cup and reset power.

Ref. 196 630 / Ref. 801 300-A

Checking Torch Shield Cup Shutdown System

CUP
TEMP

INPUT VOLTAGE

1

Power source Power switch must be reset whenever cup shutdown

system is activated. Always turn Off power source when changing or

checking consumables.