OM-227 978 Page 14

5-6.

Selecting A Location And Connecting Input Power

Y

Special installation may be
required where gasoline or
volatile liquids are present −
see NEC Article 511 or CEC
Section 20.

Y

Installation must meet all Na-
tional and Local Codes −
have only qualified persons
make this installation.

Y

Disconnect and lockout/tag-
out input power before con-
necting input conductors
from unit.

Y

Always connect green or
green/yellow conductor to
supply grounding terminal
first, and never to a line ter-
minal.

1

Rating Label

Supply correct input power.

2

Black And White Input
Conductor (L1 And L2)

3

Green Or Green/Yellow
Grounding Conductor

4

Input Power Cord.

5

Disconnect Device (switch
shown in the OFF position)

6

Disconnect Device Grounding
Terminal

7

Disconnect Device Line
Terminals

Connect green or green/yellow
grounding conductor to disconnect
device grounding terminal first.

Connect input conductors L1 and
L2 to disconnect device line
terminals.

8

Receptacle (NEMA 6-50R)

Connect receptacle as shown.

9

Over-Current Protection

Select type and size of over-current
protection using Section 5-7 (fused
disconnect switch shown).

Close and secure door on disconnect
device. Remove lockout/tagout
device, and place switch in the On
position.

10 Plug (NEMA 6-50P)

Connect plug to receptacle.

ssb2.2* 1/94 − 804 687-A

18 in (457 mm) of
space for airflow

L1

L2

230 VAC, 1

8

Y

Do not move or operate
unit where it could tip.

10

1

1

=GND/PE Earth Ground

2

L1

L2

5

4

3

6

7

9