Hearth & Home Technologies • Grand Oak Match Light Gas Log Sets • 4004-300 Rev D • 05/08

4

D. Appliance Certification

This appliance has been evaluated by Omni in accordance

with the requirements of Ansi Z2.84-2004 Standard for

Decorative Log Sets for Installation in Wood Burning Fire-

places

. Installation and the provisions for combustion and

ventilation air must conform to the

National Fuel Gas Code,

ANSI Z223.1/NFPA 54, or the CSA B149.1, Natural Gas

and Propane Installation Code.

This appliance must have a screen in place while the

appliance is in operation and, unless other provisions for

combustion air are provided, the screen shall have an

opening for introduction of combustion air.

• Solid fuels shall not be burned in a fireplace where a

decorative appliance is installed.

• If glass doors are present, the

glass doors must be fully

opened while appliance is in operation.

Do NOT use this appliance if any part has been under

water. Immediately call a qualified service technician

to inspect the appliance and to replace any part of the

control system and any gas control which has been

under water.

WARNING

E. Gas Supply Connection

A 3/8 in. flared fitting has been installed on the gas valve

inlet at the factory. Ensure fittings are of the appropriate size

and type on the gas line connection. If the tubing has to be

cut to length be sure to use the proper cutting and flaring

tool. Also, be careful not to crimp the tubing while bending. If

the tubing becomes crimped, do not use for installation.
Gas resistant pipe compound must be used on all threaded

male connections to ensure a tight seal.

F. Gas Pressure

Proper input pressures are required for optimum appliance

performance. Gas line sizing requirements need to be made

following

NFPA51.

Fire Risk

Explosion Risk
Verify inlet pressures.

• High pressure may cause overfire

condition.

• Low pressure may cause explosion.
Install regulator upstream of valve if line

pressure is greater than /2 psig.

WARNING

Fire Risk

Explosion Risk
High pressure will damage valve.

• Disconnect gas supply piping BEFORE

pressure testing gas line at test pressures

above /2 psig.

• Close the manual shutoff valve BEFORE

pressure testing gas line at test pressures

equal to or less than /2 psig.

WARNING

• Gas Supply Pressure: Minimum inlet gas supply pressure

must be 7.0 in. W.C. for natural gas. The gas line

supplying the appliance must be sufficient size to furnish

the appropriate supply pressure to the appliance while

operating in the “High” setting.

• Pressure tap screws must be closed before turning gas

on to the appliance.

• Gas Line Pressure Test: Perform pressure test according

to state and local code (if pressure exceeds /2 in. psi (3.5

kPa)) before appliance is connected. Be sure to release

air pressure from the gas line before connection is made

to the appliance. Excessive pressure will damage the gas

control and may cause a gas leak.

• Gas Leak Test: Make sure the gas connections are tight.

Turn on the gas and coat each joint with a non-corrosive

gas leak check solution. Air bubbles will form indicating

any leaks. DO NOT USE A FLAME OR ANY TYPE OF

IGNITION SOURCE TO CHECK FOR LEAKS. All leaks

must be corrected before proceeding with installation.

• The appliance must only be installed in a solid-fuel burning

fireplace with the flue damper clamped open according

to Tables  and 2. The fireplace must be constructed of

non-combustible material.

• The minimum permanent free opening (in square inches)

that must be provided by the fireplace chimney or damper

to vent the flue gases is provided in Tables 1 and 2. If the

free opening is smaller than the specified area, do not use

this appliance.

• The damper must be removed or fixed in a manner in

which will secure it open. Some jurisdictions require the

damper to be removed or permanently welded fully open.

Check with state and local codes.

• Be sure that the chimney is completely unobstructed to

ensure proper ventilation of flue gases including carbon

monoxide (CO). CO (a poisonous gas) is tasteless,

odorless, colorless and undetectable without proper

equipment.

• Refer to Table 3 to determine minimum fireplace opening

requirements before proceeding.