K. Inspect the Venting System

The fireplace venting system is designed and constructed to

develop a positive flow adequate to remove flue gases to the

outside atmosphere. See fireplace installation instructions.

A spillage test must be made before the installed

appliance is left with the consumer.

• Close all doors and windows in the home.

• Light the log set (see Lighting Instructions).

• After three minutes, test with a smoke match, smoke

candle, stick incense or cigarette  in. below the top of

the opening (lintel) moving across the full width. If spillage

(smoke down into the room) occurs, it will most likely be

near the top, outside corners.

Possible cures if spilling occurs:

• The damper needs to be opened further.

• The fireplace opening needs to be reduced by adding a

drop panel across the top under the lintel.

• The air supply from outdoors needs to be increased. Open

the outside air kit if the appliance is so equipped, or crack

open a door or window.

• If necessary, seek expert advice. Do not operate this

appliance.

Cleaning

• Periodic examination and cleaning of the venting system

of the fireplace should be done before initial use and at

least annually by a qualified agency.