KRA 405B RADAR ALTIMETER INSTALLATION MANUAL

Page 2-16

006-10536-0010 Rev. 10

Oct/2005

FIGURE 2-4 KRA 405B POST INSTALLATION CALIBRATION SWITCH

Verify proper on ground performance after the calibration is

complete. For systems without a zero feet offset programmed into the

configuration module, this will be an indication of zero feet plus

or minus the system tolerance of two or three feet. For systems with

a zero feet offset programmed into the configuration module, this

will be an indication of the negative value of the zero feet offset

plus or minus the system tolerance of two or three feet. Note that

the analog indicators may not allow quantifiable negative

indications.

A KRA 405B with software 01/04, 02/04, or higher contain

enhancements to the calibration routine.

1.

When the calibration is in process, the KRA 405B will output

an altitude of 500 feet. This relieves the 10-second switch

requirement. The switch may be released as soon as the indi-

cator displays 500 feet. If the indicator does not display 500

feet, the switch has not been adequately pressed.