KRA 405B RADAR ALTIMETER INSTALLATION MANUAL

Page 3-4

006-10536-0010 Rev. 10

Oct/2005

3.3

SELF-TEST DIAGNOSTICS

SYMPTOM

ACTION REQUIRED

Altimeter does not indicate 50

± 5 feet.

The Radar Altimeter System is in-

operative. Repair is required.

Flag does not come into view,

but indicated altitude is cor-

rect.

Indicator Failure. Radar Altime-

ter System failures may not be

indicated by a flag. Repair is

required.

DH Lamp fails to light.

Indicator Failure. The decision

height will not be annunciated.

Repair is required.

The altimeter indicates 100

feet.

The system’s receiver/transmit-

ter is inoperative. Repair is re-

quired.

The altimeter indicates 200

feet.

Configuration module failure. Re-

pair is required. (This is ap-

plicable in systems that have

configuration modules).