EVA Starter Kits, EVA4100

EVA6100

EVA8100

Controller Model

HSV200-B

HSV200-B

HSV210-B

Controller Cache

4 GB per controller pair standard 4 GB per controller pair standard 8 GB per controller pair standard

Battery Backup for Cache

Yes, up to 96 hours

Yes, up to 96 hours

Yes, up to 96 hours

Virtual Controller Software
(VCS)

HP StorageWorks
EVA4x00/6x00/8x00 XCS
v6.110

HP StorageWorks
EVA4x00/6x00/8x00 XCS
v6.110

HP StorageWorks
EVA4x00/6x00/8x00 XCS
v6.110

Host Interface

Fibre Channel Switched Fabric

Fibre Channel Switched Fabric

Fibre Channel Switched Fabric

Host Ports per Controller

Dual 4Gb/s FC enabled (running
at 2 or 4 Gb/s with 2 or 4 Gb/s
switches and HBAs)

Dual 4Gb/s FC enabled (running
at 2 or 4 Gb/s with 2 or 4 Gb/s
switches and HBAs)

Four 4Gb/s FC enabled (running
at 2 or 4 Gb/s with 2 or 4 Gb/s
switches and HBAs)

Drive Interface

Two 2Gb/s FC-AL ports per
controller in redundant pairs, two
paths to each dual ported HDD

Two 2Gb/s FC-AL ports per
controller in redundant pairs, two
paths to each dual ported HDD

Four 2Gb/s FC-AL ports per
controller in redundant pairs, two
paths to each dual ported HDD

RAID Levels

Vraid0, Vraid1, Vraid5 & Cross
Vraid Snaps

Vraid0, Vraid1, Vraid5 & Cross
Vraid Snaps

Vraid0, Vraid1, Vraid5 & Cross
Vraid Snaps

Maximum Disks
Supported

56 per Controller Pair

112 per Controller Pair

240 per Controller Pair (168 in
one cabinet, expandable to 240
with an optional expansion
cabinet.)

JBOD Support
(behind XP)

Yes

Yes

Yes

Fibre Channel Switches &
Directors

Optical Switches and Directors:

http://h18006.www1.hp.com/storage/saninfrastructure/switches.html

O/S Support

HP-UX
HP OpenVMS
HP Tru64 UNIX
Windows XP Professional
Windows 2000 Server & Advanced Server
Windows 2003 Standard/Enterprise (32/64-bit) and Extended/DataCenter (64-bit)
Sun Solaris
Linux
IBM AIX
Novell NetWare
VMware
Apple Mac OSX

NOTE: See Operating System, Cluster and High Availability Compatibility matrix above for Operating
System version detail.

Sustained I/O and MB
Throughput

Greater than 154,000 and over
1380 MB/s

Greater than 154,000 and over
1380 MB/s

Greater than 225,000 and over
2450 MB/s

Redundant Blowers

Yes

Yes

Yes

Environmental Monitoring
Unit

Yes. Monitors Power and
Temperature

Yes. Monitors Power and
Temperature

Yes. Monitors Power and
Temperature

Regulatory approvals

UL, CSA, TUV, FCC, CE MARK,
CTICK, BSMI, VCCI

UL, CSA, TUV, FCC, CE MARK,
CTICK, BSMI, VCCI

UL, CSA, TUV, FCC, CE MARK,
CTICK, BSMI, VCCI

QuickSpecs