Quickspecs – HP EVA4100 User Manual

Page 41

Advertising
background image

3.

Compatible with EVAs (EVA4100/6100/8100 arrays only). Up to four drive
enclosures are supported with each pair of HSV200 controllers (EVA4100 Starter Kits,
EVA4100/6100) without a loop switch and up to 8 with 2 loop switches. Up to 18
drive enclosures are supported with each pair of HSV210-B (EVA8100) and 4 loop
switches.
M5314C FC Drive Enclosure
The M5314C is a 3U dual-redundant FC Loop 14-bay disk enclosure with mounting
hardware, and the necessary copper FC cables for connecting to an HSV200B
Controller pair.

NOTE: A Minimum of eight disk drives of Fibre Channel or eight disk drives of FATA
are required.

*0D1 will appear after this part number on your sales order when factory integration is
indicated.

Dual FC Loop
Switch Option

Select the EVA Dual FC Loop Switch Option for EVA4000 Starter Kits, EVA4000
configurations when future expansion greater than a 2C4D configuration is expected.
The EVA Dual FC Loop Switch Option can also be field installed to an EVA4000 to
upgrade to an EVA6000.
The EVA8000-A FC Loop Switch Option for the EVA8000-A 2C2D configuration is
required for configurations above 4 enclosures.

EVA Dual FC Loop Switch Option for EVA6x00
Contains two FC loop switches, mounting hardware and cables.

AD557B

*

EVA8x000 FC Loop Switch Option
Contains 4 FC loop switches, mounting hardware and cables

AD553B

*

Enterprise Virtual Array
Racking for Expansion

The EVA customers have the option to mount supported devices in the rack used for
EVA8x00 expansion.
EVA 42U HP 10000 G2 Series Rack
Power requirements vary based on the equipment to be placed in the rack and the
country power supply. Options are:

AF002A

HP PDU Pivot Kit
Used when expanding an existing EVA8x00 to 2C12D. It may also be used to reclaim
2U of space in a 10000 G2 Series Rack with other EVA configurations. EVA8000
2C12D configured in the factory include the PDU Pivot kit as part of the standard
configuration.

AG730A

Modular PDU 24A Low Volt, NA/JPN

252663-D71

#0D2

Modular PDU 24A HV, NA/JPN

252663-D72

#0D2

Modular PDU 32A HV, INTL

252663-B31

#0D2

NOTE: #0D2 feature code designates the PDU is mounted horizontally in the bottom of
the rack on real rail, above any UPS, and occupies 1U EIA space

Low voltage PDU 252663-D71 requires additional power distraction module AF500A.
(1) AF500A supports 2 PDUs

AF500A

QuickSpecs

HP StorageWorks Enterprise Virtual Array Family

Configuration Information and Configuration Rules

DA - 12745 Worldwide QuickSpecs — Version 5 — 2.26.2008

Page 41

Advertising
This manual is related to the following products: