Rps/eps operation, Installing the switch installation procedures – HP 6400CL User Manual

Page 35

Advertising
background image

2-17

Installing the Switch

Installation Procedures

In

sta
lli

ng th

e Swi

tch

The following picture demonstrates and example of connectivity between an
RPS/EPS device and a Switch device.

RPS/EPS Operation

The RPS/EPS monitors the power signal from the switch by detecting that the
RPS/EPS is connected to a switch with an RPS/EPS cable. When the power
from the switch is no longer detected, the RPS/EPS will turn on and provide
power to the switch within 1ms.

The RPS/EPS supports hot plugging of the RPS/EPS cable without causing a
reboot of the switch or causing the power supply in either the RPS/EPS or
switch to shut down temporarily or permanently. For more information refer
to the documentation that came with the RPS/EPS.

Device Connected

Power Status

R1

R2

R3

R4

R5

R6

E1

Device

Connected
Power

Status

E2

RPS 1

RPS 2

RPS 3

RPS 4

RPS 5

RPS 6

EPS 1

EPS 2

EPS Power: 50V 370W total for PoE applications. Power is shared when both ports are used.

RPS Power: 12V backup to one connected device. Lowest-numbered port has priority.

Line: 50/60 Hz.
10

0

-2

40 V~ 9.1A (9,1A)

Switch 6400cl device,

RPS input port

RPS output port

Advertising