HP 6400CL User Manual

Page 52

Advertising
background image

4-4

Troubleshooting
Diagnosing with the LEDs

Troub

lesh

ooti

n

g

Diagnostic Tips:

Tip

Problem

Solution

The switch is not
plugged into an
active AC power
source, or the
switch’s power
supply may have
failed.

1. Verify the power cord is plugged into an active power source and to the switch. Make

sure these connections are snug.

2. Try power cycling the switch by unplugging and plugging the power cord back in.
3. If the Power LED is still not on, verify that the AC power source works by plugging

another device into the outlet. Or try plugging the switch into a different outlet or try a
different power cord.

If the power source and power cord are OK and this condition persists, the switch power
supply may have failed. Call your ProCurve authorized LAN dealer, or use the electronic
support services from ProCurve to get assistance. See the Customer Support/Warranty
booklet for more information.

A switch
hardware failure
has occurred. All
the LEDs will stay
on indefinitely.

Try power cycling the switch. If the fault indication reoccurs, the switch may have failed.
Call your ProCurve authorized LAN dealer, or use the electronic support services from
ProCurve to get assistance. See the Customer Support/Warranty booklet for more
information.

The switch has
experienced a
software failure
during self test.

1. Try resetting the switch by pressing the Reset button on the front of the switch, or by

power cycling the switch.

2. If the fault indication reoccurs, attach a console to the switch (as indicated in chapter

2) and configure it to operate at 9600 baud. Then, reset the switch. Messages should
appear on the console screen and in the console log identifying the error condition.
You can view the console log at that point by selecting it from the console Main Menu.

If necessary to resolve the problem, contact your ProCurve authorized LAN dealer, or use
the electronic support services from ProCurve to get assistance. See the Customer
Support/Warranty booklet for more information.

One or more of
the switch
cooling fans may
have failed.

Try disconnecting power from the switch and wait a few moments. Then reconnect the
power to the switch and check the LEDs again. If the error indication reoccurs, one or
more of the fans has failed. The switch may continue to operate under this condition if
the ambient temperature does not exceed normal room temperature, but for best
operation, the switch should be replaced. Contact your ProCurve authorized LAN dealer,
or use the electronic support services from ProCure to get assistance. See the Customer
Support/Warranty booklet for more information.

The network port
for which the LED
is blinking has
experienced a
self test or
initialization
failure.
If the Mdl Status
LED is blinking,
the affected port
is on the cl
Module.

Try power cycling the switch. If the fault indication reoccurs, the switch port may have
failed. Call your ProCurve authorized LAN dealer, or use the electronic support services
from ProCurve to get assistance. See the Customer Support/Warranty booklet for more
information.
If the port is a transceiver, verify it is one of the transceivers supported by the switch.
Unsupported transceivers will be identified with this fault condition. The supported
transceivers are listed in the ProCurve Switch cl Modules Installation Guide.
To verify the port has failed, try removing and reinstalling the transceiver without having
to power off the switch. If the port fault indication reoccurs, you will have to replace the
transceiver.

continued on the next page