GROUNDING THE

GENERATOR

The National Electrical Code requires that the frame and
external electrically conductive parts of this generator be
properly connected to an approved earth ground. Local
electrical codes may also require proper grounding of the
unit. For that purpose, a GROUNDING FASTENER is
provided on the generator end (Figure 2).

Generally, connecting a No. 12 AWG (American Wire
Gauge) stranded copper wire to the grounding fastener and
to an earth–driven copper or brass grounding rod
(electrode) provides adequate protection against electrical
shock. Be careful to keep the grounding wire attached after
connecting the stranded copper wire. However, local codes
may vary widely. Consult with a local electrician for
grounding requirements in your area.

Properly grounding the generator helps prevent electrical
shock if a ground fault condition exists in the generator or
in connected electrical devices, especially when the unit is
equipped with a wheel kit. Proper grounding also helps
dissipate static electricity, which often builds up in
ungrounded devices.

OPERATING THE

GENERATOR

Starting the Engine

Disconnect all electrical loads from the generator. Use the
following start instruction steps by numerical order:

1.

Make sure unit is on a level surface.

IMPORTANT: Failure to start and operate unit on a level
surface will cause the unit not to start or shut down during
operation.

2.

Turn fuel valve to “On” position (Figure 3).The fuel
valve handle should be vertical (pointing toward
ground) for fuel to flow.

3.

Make sure Idle Control switch is in “Off” position
(Figure 4).

Fuel Valve is shown
in the “On” position

Figure 3 — Fuel Valve

Figure 2 — Grounding Fastener

Grounding
Fastener

Figure 4 — Idle Control Switch

• See “Don’t Overload Generator” on page 13.

• Start generator and let engine stabilize before connecting

electrical loads.

• Connect electrical loads in OFF position, then turn ON for

operation.

• Turn electrical loads OFF and disconnect from generator

before stopping generator.

Exceeding generator’s wattage/amperage capacity can
damage generator and/or electrical devices connected
to it.

CAUTION