Enww troubleshooting menu 57 – HP CM6049F MFP User Manual

Page 73

Advertising
background image

Menu item

Sub-menu item

Sub-menu item

Values

Description

Repeat

Once

(Default)

Continuous

Determines the number of times the test runs.

Print/Stop Test

Continuous value
from 0 to 60,000
milliseconds.
Default: 0

Isolate faults by stopping the device during
the print cycle and observing where in the
process the image degrades. To run the test,
specify a stop time. The next job that is sent
to the device stops at the specified time in the
process.

Color Band Test

Test Page

Print

Prints a page that helps identify arcing in the
high-voltage power supplies.

Copies

Continuous value
from 1 to 30.

Default: 1

Specify the number of copies to print for the
Color Band test

Scanner Tests

Lower Lamp

Sensors

ADF Input Motor

ADF Input Reverse

Flatbed Motor

ADF Read Motor

ADF Read Motor
Reverse

ADF Duplex
Solenoid

ADF LED Indicator

A service technician can use this menu item
to diagnose potential problems with the
device scanner.

Control Panel

LEDs

Verify that the components of the control
panel are functioning correctly.

Display

Buttons

Touchscreen

Finisher Tests

Manual Sensor Test

Component Test

Table 2-17

Troubleshooting menu (continued)