3. No other fuel burning appliance shall be installed in the same closet as the gas

dryer.

4. Refer to the images on this page to ensure the installation provides the

minimum amount of clearance required for ventilation.

5. When installing the dryer in a closet with a door, a minimum of 120 square

inches (774.2 square cm) of ventilation in the door is required. Openings must

be equally divided at the top and bottom of the door and airflow must be

unobstructed. A louvered door with equivalent air openings for the length of

the door is acceptable.

1. Dryer MUST be exhausted outside (outdoors, not beneath the manufactured

home) using metal ducting that will not support combustion. Metal ducting must

be 4 inch (10.16 cm) in diameter with no obstructions. Rigid metal duct

is preferred.

2. If dryer is exhausted through the floor and area beneath the manufactured

home is enclosed, the exhaust system MUST terminate outside the enclosure

with the termination securely fastened to the mobile home structure.

3. When installing a gas dryer into a manufactured home, a provision must be

made for outside make up air. This provision is to be not less than twice the

area of the dryer exhaust outlet.

4. This dryer MUST be fastened to the floor using. Manufactured Home

Installation Kit. Follow the instructions supplied with the kit.

5. Refer to previous sections for other important venting requirements.
6. Installation must conform to current Manufactured Home Construction & Safety

Standard (which is a Federal Regulation Title 24 CFR-Part 32-80) or when

such standard is not applicable, with American National Standard for Mobile

Homes. In Canada, the CSA Z240 is applicable.

MANUFACTURED (MOBILE) HOME INSTALLATION