Special Instructions

Hot Water Out

Cold Water In

Pressure

Relief Valve

Existing Water

Heater

Rear Of

Furnace

Automatic

Air Valve

Pressure

Relief Valve

(Must be within

2 feet of coil)

10 Feet Maximum

Drain

Valve

1

2

3

3

4

5

Plumbing diagram For Thermo-Siphon method - maximum distance = 10 Feet

Place one of the supplied nuts on each leg of the coil. Place the coil through the holes on the back of

the furnace, and adjust the nuts so that the pipes stick out about ¼ to ½ inches from the rear of the

furnace. Place the flat washers and gaskets over each pipe and tighten the nuts. You are now ready

to run the piping.

This simple method is the most economical. However, the existing water heater must be less than

0 feet from the furnace. The water inlet, where the Temperature / Pressure Relief valve is located,

must be higher than the top leg of the water coil. The water heater should be elevated, if necessary,

to allow for proper thermo-siphon action.(The method by which hot water will circulate automatically

through the system.)

A. Shut off the water heater and the water supply to it. Drain the tank completely.

B. Remove the Temp. / Presure relief valve and discard. Install a short 3/4 in. nipple and tee () along

with a new relief valve.

C. run 3/4 in. copper tubing between the water tank and the top leg of the coil. Install a 3/4 in vent

elbow and automatic “float type” air vent (2) in the high point of the line. Within 2 feet of the top leg of

the coil, install a 50 lb. pressure relief valve (5). Run 3/4 in. tubing from the release exit of both relief

valves downward (3) so the hot water can escape in the event of an overheat situation.

D. Remove the drain valve, at the bottom of the tank. Install a short 3/4 in. nipple and tee and re-

install the drain valve to the tee (4). Run 3/4 in. tubing between the drain / tee combination and the

lower leg of the water coil. After all of the connections are secured, refill the water tank. Turn on the

water heater only after the tank has been completely refilled.