Fig. 4 – Hoshizaki SELF-CONTAINED CRESCENT CUBER L1F015102 User Manual

Page 13

Advertising
background image

10

* Drain lines should not be piped directly to the sewer system. An air gap of a minimum of

2 vertical inches (5 cm) should be between the end of the drain pipes from the icemaker
and the floor drain.

* This icemaker should be installed in accordance with applicable national, state and local

regulations.

* A plumbing permit and services of a licensed plumber may be required in some areas.

Fig. 4

KM-201BAH
KM-260BAH

Water Supply Inlet
1/2” FPT

Drain Outlet
3/4” FPT

Shut-off Valve

To approved floor drain

Two-inch (5 cm)
air gap

Drain

Floor

Separate piping to approved drain.
Leave a two-inch (5 cm) vertical air
gap between the end of each pipe
and the drain.

Drain Valve

1/4” fall per foot