Prior to installation, ensure that the local distribution

conditions (nature of the gas and gas pressure) and

the adjustment conditions are compatible. The

adjustment conditions for this appliance are stated

on the data badge which is fitted on the back panel.

This appliance is not designed to be connected to a

combustion products evacuation device. It must be

installed and connected in accordance with current

installation regulations. particular attention should be

given to the relevant requirements regarding

ventilation.

MODEL NUMBERS EG94

Category II2H3+ (GB)

These models are set to burn NATURAL GAS (G20)

at 20 mbar but can be converted for use on BUTANE

(G30) at 28-30mbar or PROPANE (G31) at 37mbar

with the use of the LPG conversion kit that can be

obtained free of charge, if you contact our Genuine

Parts and Accessories department (see back page).

GAS SAFETY (INSTALLATION & USE)

REGULATIONS

It is the law that all gas appliances are installed by

competent persons in accordance with the current

edition of the above regulations. It is in your interest

and that of safety to ensure compliance with the law.

In the UK, CORGI registered installers work to safe

standards of practice. The cooker must also be

installed in accordance with BS 6172. Failure to

install the cooker correctly could invalidate the

warranty liability claims and could lead to

prosecution.

Installation Instructions

LOCATION

The cooker may be located in a kitchen, kitchen/

diner or a bed-sitting room, but not in a room

containing a bath or shower. The cooker must not be

installed in a bed-sitting room of less than 20m

3

.

When adjusted for use on Butane (G30) or Propane

(G31), the cooker must not be installed in a room or

internal space below ground level, e.g. in a

basement.

PROVISION FOR VENTILATION

The room containing the cooker should have an air

supply in accordance with BS 5440: Part 2.

The room must have an opening window or

equivalent; some rooms may also require a

permanent vent. If the room has a volume between 5

and 10m

3

, it will require an air vent of 50cm

2

effective area unless it has a door which opens

directly to outside. If the room has a volume of less

than 5m

3

, it will require an air vent of 100cm

2

effective area. If there are other fuel burning

appliances in the same room, BS 5440: Part 2

should be consulted to determine air vent

requirements.

TECHNICAL DATA

Gas connection

Rp ½ (½" BSP female)

Pressure test point

Front left hotplate injector

Gas rate adjustment

None

Aeration adjustment

None

Electrical connection

4mm

2

twin and earth

230/240V a.c. 50Hz.

EG94

G20 at 20mbar

G30 at 28-30mbar

G31 at 37mbar

Burner

HEAT INPUT

INJECTOR

HEAT INPUT

INJECTOR

HOTPLATE

Front Left

3.9 kW

131

3.5 kW (255g/h)

87

HOTPLATE

Rear Right

3.0 kW

116

3.0 kW (220g/h)

86

HOTPLATE

Front Right and Rear Left

2.0 kW

103

2.0 kW (145g/h)

70

TOTAL LOAD

4.5 / 4.9 kW