Electrical Connection

Warning - THIS APPLIANCE MUST BE EARTHED

The cooker must be connected by a qualified

electrician to a suitable double - pole control unit

with a minimum rating of 32A and a minimum

contact clearance of 3mm, which should be fitted

adjacent to (but not above) the cooker, in

accordance with IEE regulations.

The power supply cable should conform to BS6004

with a conductor size of 4mm

2

.

The control unit should be easily accessible in the

event of an emergency.

This appliance conforms to EN55014 regarding

suppression of radio and television interference.

Access to the cooker terminals is by un-clipping the

cover. The mains cable must pass through the cable

clamp and the screws must be fully tightened.

Sufficient cable should be used to allow the cooker

to be pulled out for servicing. Ensure that the cover

is fully closed and secure afterwards.

Take care not to trap the mains cable when pushing

the cooker into its final position.