Hitachi CP-X1250 User Manual

Page 44

Advertising
background image

44

T

T

roubleshooting (continued)

roubleshooting (continued)

Regarding The Indicator Lamps (continued)

STANDBY/ON

indicator

LAMP

indicator

TEMP

indicator

Description

Lighting

in

Red

Blinking

in

Red

Turned

off

Either there is no lamp and/or lamp cover, or
either of these has not been properly fixed.

Please turn the power off, and allow the unit to cool down at
least 45 minutes. After the projector has sufficiently cooled
down, please make confirmation of the attachment state of
the lamp and lamp cover, and then turn the power on again.
If the same indication is displayed after the treatment,
please contact your dealer or service company.

Lighting

in

Red

Turned

off

Blinking

in

Red

The cooling fan is not operating.

Please turn the power off, and allow the unit to cool down at
least 20 minutes. After the projector has sufficiently cooled
down, please make confirmation that no foreign matter has
become caught in the fan, etc., and then turn the power on
again.
If the same indication is displayed after the treatment,
please contact your dealer or service company.

Lighting

in

Red

Turned

off

Lighting

in

Red

There is a possibility that the interior portion has
become heated.

Please turn the power off, and allow the unit to cool down at
least 20 minutes. After the projector has sufficiently cooled
down, please make confirmation of the following items, and
then turn the power on again.
• Is there blockage of the air passage aperture?
• Is the air filter dirty?
• Does the peripheral temperature exceed 35°C?
If the same indication is displayed after the treatment,
please change the lamp by referring to the section “Lamp”.

Lighting

in

Green

Alternative

Blinking in

Red

There is a possibility that the interior portion has
become overcooled.

Please use the unit within the usage temperature
parameters (0°C to 35°C). After the treatment, resent the
power to ON.

Lighting

in

Green

Simultaneous

Blinking in

Red

It is time to clean the air filter, or there is no air
filter.

Please immediately turn the power OFF, and clean or
change the air filter by referring to the section “Air Filter”.
After cleaning or changed the lamp, please be sure to reset
the filter timer. After the treatment, resent the power to ON.

Advertising