Harbor Freight Tools CentalPneumatic Coil Roofing Nailer 68024 User Manual

Page 12

Advertising
background image

Page 12

For technical questions, please call 1‑800‑444‑3353.

SKU 68024

stop immediately and take the tool to a

qualified service technician.

7. Press the Safety Nosepiece against

the workpiece and squeeze the Trigger.

The tool must cycle (fire) only once.

Release the trigger and squeeze it

again.

The tool must cycle (fire)

again only once. With the Trigger

held, carefully lift the tool and press it

against the workpiece again.

The tool

must cycle (fire) again only once. If

it fails to act in the manner explained

in bold, have it repaired by a qualified

service technician.

Single Sequential Safety Trip

Mechanism Definition

The Single Sequential safety trip

mechanism is designed to prevent inadvertent

firing. To set the Nailer in the Single

Sequential mode, turn the Mode Switch to the

Single Sequential position (as indicated by the

single bump fire symbol).

The tool should only fire if the Safety

Nosepiece is pressed against the workpiece

prior to pulling the Trigger. It should only fire

again if the trigger is released and squeezed

again. The Tool should not fire if the Safety

Nosepiece is not pressed against an object.

Single Sequential Safety Trip

Mechanism Testing Procedure

TO PREVENT

SERIOUS INJURY

FROM ACCIDENTAL

OPERATION: Empty the tool

before this procedure. Point the

tool at a piece of scrap wood

when testing.

1. Disconnect the tool from the air supply.
2. Empty the magazine of fasteners.

3. Check that the Trigger and the Safety

Nosepiece move freely, without sticking.

4. Connect the air supply to the tool and

set within the Operating Air Pressure

indicated on the Specification chart.

5. Test the tool by pressing the Safety

Nosepiece against the workpiece

without pulling the Trigger.

The tool

must not cycle (fire). If it cycles (fires),

stop immediately and take the tool to a

qualified service technician for repair.

6. Hold the tool away, or off of the

workpiece. The Safety Nosepiece

should return to its original position.

Squeeze the Trigger.

The tool must

not cycle (fire). If it cycles (fires),

stop immediately and take the tool to a

qualified service technician.

7. Press the Safety Nosepiece against

the workpiece and squeeze the Trigger.

The tool must cycle (fire) only once.

Release the trigger and squeeze it

again.

The tool must cycle (fire)

again only once. With the Trigger

held, carefully lift the tool and press

it against the workpiece again.

The

tool must not cycle (fire). If it fails

to act in the manner explained in

bold, have it repaired by a qualified

service technician.

Advertising