FUNCTIONAL DESCRIPTION

Specifications

Max. Air Pressure 120 PSI
Air Inlet

1/4” -18 NPT

Air Consumption 1 CFM @ 90 PSI
Fastener

Capacity

11 Gauge, 3/4” to 1-3/4” Wire-

Collated Roofing Nails

Magazine

Capacity

120

Components and Controls

Safety Nosepiece - Also called the workpiece

contact, the Safety Nosepiece helps

prevent the tool from firing unless it is

pressed against an object.

Depth Knob - This controls the nail depth.

Push the Knob to the left for shorter nails

(or to fire nails less deep). Push the

Knob to the right for longer nails (or for

deeper depths).

Roofing Gauge - This can be adjusted to

guide the shingle spacing. Loosen the

Cap Screw, adjust Gauge as needed,

then retighten the Cap Screw.

INITIALASSEMBLY

Read the ENTIRE IMPORTANT

SAFETY INFORMATION

section at the beginning of this

manual including all text under

subheadings therein before set up

or use of this product.

Note: For additional information regarding the

parts listed in the following pages, refer

to the Assembly Diagram near the end of

this manual.

Unpacking

When unpacking, make sure that the

item is intact and undamaged. If any parts

are missing or broken, please call Harbor

Freight Tools at 1-800-444-3353 as soon as

possible.

• This air tool may be shipped with a

protective plug covering the air inlet.

Remove this plug before set up.

Air Supply

TO PREVENT

EXPLOSION:

Use only clean, dry, regulated,

compressed air to power this

tool. Do not use oxygen, carbon

dioxide, combustible gases, or

any other bottled gas as a power

source for this tool.

1. Connect a regulator valve, an in-line shut

off valve, and 1/4” NPT air hose (all sold

separately) to the Quick Coupler. Use

thread tape for all threaded connections.

The air hose must be long enough to

reach the work area with enough extra

length to allow free movement while

working.

An in‑line shutoff ball valve

is an important safety device because

it controls the air supply even if the

Trigger (44)

Safety (37)

Roofing

Gauge (82)

Depth Knob

(52)

Initial Tool Setup/Assembly

Functional Description

Mode Switch (41)

Air

Inlet

(100)

Advertising