IMA M

OTOR

/ G

ENERATOR

Role

The thin design motor is located between the 3-cylinder engine and the transmission. The IMA motor

serves a number of functions:

• It assists in vehicle propulsion when needed, allowing the use of a smaller internal combustion

engine.

• It operates as a generator, allowing excess energy (such as during braking) to be used to

recharge the IMA Battery Module, and later be used to provide assist.

• It takes the place of the conventional alternator, providing energy that ultimately feeds the

Insight's conventional 12v electrical system.

• It is used to start the internal combustion engine very quickly and quietly. This allows the

internal combustion engine to be turned off when not need, without any delay in restarting on

demand.

• It is used to dampen crankshaft speed variations, leading to smoother idle.

Location

The IMA motor is located between the internal combustion engine (ICE) and clutch. One end of the

IMA motor rotor is bolted to the ICE crankshaft, and the other end of the rotor is bolted to the flywheel.

Because of the IMA motor adds rotational mass, the weight of the flywheel can be reduced by an amount

equal to the weight of the IMA motor rotor.

The flywheel retains gear teeth for the backup 12v starter motor to mesh with when it is engaged. In

manual transmission Insights, as with other manual transmission vehicles, the clutch also serves as a

surface for the clutch.