Ga-2.5h — initial start-up engine/operation – HONDA GA-2.5H User Manual

Page 24

Advertising
background image

PAGE 24 — GA-2.5H A.C. GENERATOR — OPERATION & PARTS MANUAL — REV. #4 (10/07/05)

6. If the engine has started, slowly return the choke lever

(Figure 11 ) to the

“OPEN”

position. If the engine has not

started repeat steps 1 through 5.

7. Before the generator is placed into operation, run the

engine for 3-5 minutes. Check for abnormal smells, fuel
leaks, and noises that would associate with lose compo-
nents.

8. Refer to the AC voltmeter (Figure 14) on the control

panel. The voltage indicated on the voltmeter should be
120 VAC with no load applied.

Figure 14. AC Voltmeter (120 VAC)

9. If desired, verify with a voltmeter (Figure15) that 120

VAC is present at the GFCI duplex receptacle and the
120V twist-lock receptacle.

GA-2.5H — INITIAL START-UP ENGINE/OPERATION

Connecting the Load

1. Connect the load to the output receptacles.

2. Place the main circuit breaker (Figure 16) in the ON

position.

Figure 15. 120 VAC GFCI Receptacle

Stopping The Engine

Normal Shutdown

1. Place the

main circuit breaker (Figure 9) in the OFF

position.

2. Remove the load from the generator, and let the engine

run at idle for 3-5 minutes with the idle control switch in
the ON position (Up)

3. Place the

engine ON/OFF switch

(Figure 17) in the "

OFF

"

position.

4. Place the engine

fuel valve lever

(Figure 18) to the "OFF"

position.

Emergency Showdown

1.

Place the

engine ON/OFF swith (Figure 17) in the

"OFF" position.

Figure 18. Engine Fuel Valve Lever (OFF Position)

Figure 17. Engine ON/OFF Switch (OFF)

Figure 16. Main Circuit Breaker (ON)