Mq ga-2.5h — preparation for long -term storage – HONDA GA-2.5H User Manual

Page 25

Advertising
background image

GA-2.5H A.C. GENERATOR — OPERATION & PARTS MANUAL — REV. #4 (10/07/05) — PAGE 25

MQ GA-2.5H — PREPARATION FOR LONG -TERM STORAGE

Generator Storage

For storage of the generating set for over 30 days, the
following is required:

■ Drain the fuel tank completely, or add STA-BIL to the fuel.
■ Run the engine until the gasoline in the carburetor is

completely consumed.

■ Completely drain the oil from the crankcase and refill with

fresh oil.

■ Remove the spark plug, pour 2 or 3 cc of SAE 30 oil into the

cylinder and crank slowly to distribute the oil.

■ Slowly rotate the engine a few times with the starter Rope

and install a new plug.

■ Pull out the starter rope slowly and stop at the compression

point.

■ Clean all external parts of the generating set with a cloth.
■ Cover the generating set and store in a clean, dry place.

Advertising