Operation, Warning – Homelite HP35 User Manual

Page 8

Advertising
background image

8

099597

5. Open propane supply valve on propane tank(s) slowly.

Note:

If not opened

slowly, excess-flow check valve on propane tank may stop gas flow. If this
happens, close propane supply valve and open again slowly.

OPERATION

Continued

Piezo Ignitor
Button

Automatic Control
Valve Button

Figure 5 - Automatic Control Valve Button and Piezo Ignitor Button

Notice:

If heater is unplugged or power outage occurs while heater is running, the

thermal limit device will stop fuel flow. A few seconds occur before the thermal
limit device activates. During this short time, flames may appear outside the
heater. This is normal. The flames will go out when thermal limit device activates.

To Stop Heater

1. Tightly close propane supply valve on propane tank(s). Allow heater to burn

remaining fuel in hose.

2. Wait a few seconds. Heater will burn gas left in supply hose.

3. Unplug heater.

To Restart Heater

1. Wait five minutes after stopping heater.

2. Repeat steps under To Start Heater, page 7.

6. Push in and hold automatic control valve button (see Figure 5). Push piezo

ignitor button (see Figure 5). You may need to push piezo ignitor button 3-8
times until the burner lights. When burner lights, keep automatic control valve
button pushed in. Release button after 30 seconds.

Note:

If heater fails to ignite, hose may have air in it. If so, keep automatic

control valve button pressed and wait 20 seconds. Release automatic control
valve button and wait 20 seconds for unburned fuel to exit heater. Repeat step 6.

!

WARNING

Be sure motor and fan are running before pushing in auto-
matic control valve button. Flames could flash outside
heater if motor and fan are not running.

Advertising