Series 2040 Test System

Series 2040 Maintenance Manual V2.00

Selftest & Calibration

12

:” (Colon) signifies that the following number indicates the amount

of iterations to perform of the previous sequence.

,’ (Comma) shares the definition of ‘E’ as a separator between

sequences.

-’ (Dash) signifies inclusive or ‘through’.

EXAMPLE: E1-3:5,6-100:2,1-5

This sequence executes tests 1 through 3 five times, tests 6 through

100 two times, and tests 1 through 5 once.

If a single test or a group of selected tests is to be run once, 10

times, or 100 times, use the mouse to select the appropriate button

on the upper left. If the test or group is to be run at some other

number, place the mouse pointer in the box to the direct left of the

stop button, and the Windows text tool will appear in place of the

mouse pointer. Click the left mouse button while texttool is

displayed in the box, and a blinking cursor appears in the box. The

user can now enter any number from 1 to 999 for the number of

times a test should run.

For diagnostic purposes, click

the mouse button on the small

box in the upper left corner of

the menu next to “All Tests”.

Select the “1" button, and the

program will run all of the

functional tests once, while reporting the data to wherever it was

directed from the ”Report Utilities" box. For diagnostics this path

should include the “File” and “Printer” categories, and the “Fail

Data” and “Diagnostic File” options.

5) If any of the Functional programs fail, check these common

problems:

SELFTEST ASSEMBLY IMPROPERLY INSTALLED - Check to make

sure the assembly is properly installed on the Patchboard. Also,

Advertising