C. securing and leveling the appliance, D. installing the fiberglass gasket – Heat & Glo Fireplace 8000CF-OAK-IPI User Manual

Page 33

Advertising
background image

Heat & Glo • 8000CF-OAK-IPI • 2059-900 Rev. R • 6/09

33

C. Securing and Leveling the Appliance

WARNING! Risk of Fire! Prevent contact with:

• Sagging or loose insulation

• Insulation backing or plastic

• Framing and other combustible materials
Block openings into the chase to prevent entry of blown-

in insulation. Make sure insulation and other materials

are secured.
DO NOT notch the framing around the appliance

standoffs.
Failure to maintain air space clearance may cause

overheating and fi re.

The diagram shows how to properly position and secure

the appliance (see Figure 9.4). Nailing tabs are provided

to secure the appliance to the framing members.
• Bend out nailing tabs on each side.
• Place the appliance into position.
• Keep nailing tabs fl ush with the framing.
• Level the appliance from side to side and front to back.
• Shim the appliance as necessary. It is acceptable to use

wood shims underneath the appliance.

• Secure the appliance to the framing by using nails or

screws through the nailing tabs.

• Secure the appliance to the fl oor by inserting two screws

through the pilot holes at the bottom of the appliance.

Figure 9.4 Proper Positioning and Securing of an Appliance

D. Installing the Fiberglass Gasket

The fi berglass gasket supplied in the manual bag seals

between the fi rst 8 inch (203 mm) vent component and

the outer fi replace wrap. Using 2 self-tapping screws from

the manual bag secure the gasket to the outer wrap (see

Figure 9.5).

Figure 9.5 Fiberglass Gasket

FIRST VENT

COMPONENT

FIBERGLASS

GASKET

OUTERWRAP

NAILING TABS

(BOTH SIDES)

Advertising
This manual is related to the following products: