Henny Penny COLD TOPS CMC/CMR-104 User Manual
Page 7

Model CMC/CMR-103,104,105,106,107
2-2. UNPACKING
Take care when moving the fryer to prevent personal
injury
or damage to the refrigeration system.
The
CMC-107s weigh over 700 lbs. (318 kg).
4.
Peel off any protective covering from exterior of the cabinet.
5.
Install the grids into unit.
6.
Unpack sliding thermal doors and side glass. Install on rear
and side of unit.
7.
Your cold top is now ready for operation.
2-3. ELECTRICAL
The Cold Top is available as a 120 VAC, 60 Hz. or 230VAC,
50 Hz., single phase unit, both for domestic and international use.
The data plate, located beside the power cord, specifies the correct
electrical supply. The Cold Tops are shipped with cord and plug,
and requires a grounded receptacle with a separate electrical line
protected by a fuse or circuit breaker of the proper rating. Position
the unit so the power cord receptacle is accessible.
To avoid electrical shock, this appliance must be
equipped with an external circuit breaker which will
disconnect all ungrounded (unearthed) conductors.
Refer to the table below for electrical ratings:
Model No.
Volts
Amps
Phase
Max. Fuse Size
CMC-103
120
7.7
1
15
CMC-103
230
4.5
1
15
CMC-104
120
7.7
1
15
CMC-104
230
4.5
1
15
CMC-105
120
8.6
1
15
CMC-105
230
6.0
1
15
CMC-106
120
8.6
1
15
CMC-106
230
6.0
1
15
CMC-107
120
9.5
1
15
CMC-107
230
7.7
1
15
(Continued)
2-2