General problem: no output, General problem: excessive pressure build up – haier MAGNUM 232738 User Manual

Page 17

Advertising
background image

Advanced Troubleshooting

309477F

17

General Problem: No Output

Specific Problem

Cause

Solution

Power switch is on and sprayer
is plugged in but pump does
not cycle

See Basic Troubleshooting,
page 9.

Motor runs but pump does not
cycle

Gear and/or yoke are damaged
(XR9 only)

Replace gear and yoke using Gear/Yoke Repair
Kit
, page 18.

Motor does not run

Water or paint entered
pressure control switch or
shorted control board

Clean out and/or dry out and retry. Replace if
necessary using Pressure Control Switch Kit,
page 18.

General Problem: Excessive Pressure Build Up

Specific Problem

Cause

Solution

Prime/Spray Valve actuates
automatically, relieving
pressure through drain tube.

Pressure control switch is worn Replace pressure control switch using Pressure

Control Switch Kit, page 18.

Water or paint entered
pressure control switch or
shorted control board

Clean out and/or dry out and retry. Replace if
necessary using Pressure Control Switch Kit,
page 18.

Control board failed

See Control Board Diagnostics, page 19.
Replace damaged control board using Control
Board Kit
, page 18.

Advertising