Troubleshooting schedule, Keypad, Battery – Husqvarna 536 LIL User Manual

Page 22: Battery charger, Maintenance, Battery battery charger

Advertising
background image

22 – English

MAINTENANCE

Troubleshooting schedule

Troubleshooting takes place from the keypad.

Keypad

Troubleshooting the battery and/or the battery charger during charging.

Battery

Battery charger

Control panel

Possible faults

Possible action

Green activate LED flashing.

Low battery voltage.

Charging the battery

Error LED flashes.

The power trigger and the activate
button are pressed at the same
time.

Release the power trigger and the
machine is active.

Overload.

The trimmerhead is jammed.

Remove the battery from the
machine. Release the trimmer
head from grass.

Temperature deviation.

Allow the machine to cool down.

The machine will not run

Dirt in battery connectors.

Clean with compressed air or a soft
brush.

Error LED is lit with red light.

Service

Contact your service agent.

LED display

Possible faults

Possible action

Green activate LED flashing.

Low battery voltage.

Charge the battery

Error LED flashing.

The battery is discharged.

Charge the battery

Temperature deviation.

Use the battery in surroundings
where temperatures are between -
10

°

C and 40

°

C.

Over voltage.

Check that the mains voltage
corresponds with that stated on the
rating plate on the machine.

Remove the battery from the
battery charger.

Error LED is lit.

Cell difference too much (1V).

Contact your service agent.

LED display

Possible faults

Possible action

Error LED flashing.

Temperature deviation.

Use the battery charger only when
the surrounding temperature is
between 5

°

C and 40

°

C.

Error LED is lit.

Contact your service agent.

Advertising
This manual is related to the following products: