Air does not blow or the fan speed cannot be
changed during the dehumidifying mode.

Water or steam generates from the outdoor unit
during heating.

During heating, the fan in the indoor unit still
works even after the unit operation stops.

There would be sooting around the outlet and a
sound

Si Si

would be heard.

Is power switch on?

The air conditioner cannot be started

Is power supply normal?

Is the leakage breaker tripped?

Please switch off the power
supply

immediately

and

contact the local maintenance
center.

The power switch is not on the
position

ON

.

During the dehumidifying operation, when the
room temperature is less than 2

higher than

the temperature set, the air conditioner will
operate at low

fan

speed intermittently

regardless to the fan speed set.

This results from removal of the frost
accumulated on the outdoor unit (Defrosting
operation).

To eliminate the afterheat, the fan in the indoor
unit will still operate for a while after the unit
automatically stops.

It is due to the accumulation of anion, which
can be cleaned after the unit is turned off. The
sound "Si Si" is due to generation of anion.

Please check your air conditioner as the procedure below before contacting the local maintenance

center for after sales service:

20

ON

OFF

Power cut?

Trouble Shooting

When your remote controller is lost or cannot be used, the unit can be operated with a
function of emergency operation.
The test operation can be applied when the cooling test operation is carried out under the
room temperature of 16

.

It can only be used when the remote controller is lost or damaged.

Press the emergency manual button, you will hear a sound

Hua

, then the emergency

operation begins. This time the power or healthy operation indicat r lamp on the indoor
unit lights up.

Turning on

The air conditioner will automatically run as the mode below:

o

During emergency operation, the temperature set and air speed
cannot be changed. Besides, the dehumidifying and timer operation
cannot be operated either.

Turning Off(Cancel Emergency Operation)

Cancel Emergency Operation with Remote Controller

Press the

Emergency Manual Operation

button, you will hear a

sound

Hua

, then all the indicators will go out .

Press the

On/Off

button, you will hear a sound

Hua

, then

the air conditioner will work as the mode indicated on the remote

controller.

This is for test cooling operation under 16

indoor temperature.

It cannot be used under normal condition.

Turning On

Turning Off (Cancel Test Operation)

Cancel Test Operation with Remote Controller

Keep pressing the

Test Manual button

button for 5 seconds,

you will hear sound

Hua

Hua", then release the pressing ,

then the test operation begins. Now the unit works under

Hi

air speed, and the power or healthy operation indicator on the
indoor unit lights up.The air conditioner will be automatically
turned off after test operation lasts 30 minutes.

Press the

Test manually button

, you will hear a sound

Hua

,

then all the indicators on the unit will go out.

Press the

On/Off

button, you will hear a sound

Hua

, then

the air conditioner will work as displayed on remote controller.

Emergency Operation & Test Operation

Emergency Operation

Test Operation

indoor temp

Above 23

Below 23

26

23

No

No

Auto

Auto

No

No

Cooling

Heating

Temp set

Timer

Air speed

Mode

Health
Operation

13

Operation

Hua!

Hua!

Hua!