Name of Parts

Introduction to Display and Function:
1. Mode

Mode selected is displayed

2. Air Volume

Indicating the air speed, when

automatic

is set, the air speed changes according to the temperature

difference between the indoor temperature and set temperature.

3. Healthy Operation

Indicating healthy operation

4. Timing Mode Display

Indicating time set mode:

Normal

for non-time-set;

Timed off

for timed turning off;

Timed on

for timed turning on;

5. Indicating the Time set

Indicating the time set on and off

6. Mode Selection

Selecting the modes below:
cooling, dehumidifying, and heating

7. Timer

Used to select TIMER ON, TIMER OFF

8. Time Set

To set the time on and off

9. Signal Sending Head

To send signal into the signal receiver on the indoor unit

10. Signal Display

It blinks when the signal is being sent

11. Temperature Display

To display the temperature set

12. Temperature Set

To set the desired room temperature

13. On/Off Button

To turn on and turn off the air conditioner

14. Air Volume

To select the desired air speed

15. Air flow Direction

To adjust the air flow direction

16. Healthy Button

To set the healthy operation

17. Power Button

To set super or soft operation

18. Indication for Power Operation
19. Reset

When the remote controller appears abnormal,
use a sharp pointed item to press this button to
reset the remote controller to normal condition.

Notes: After replacing the batteries in the remote controller, press on/off button, the mode is resumed

as below:
Mode: Refrigerating; Temperature:26
Timer: Normal; Fan Speed: Automatic

4

Remote Controller:

AUTO

C

ON OFF

H

ion

1

9

10

11

18

12

13

14

15

8

2

3

4

5

6

7

17

19

16

FAN

HEALTH

POWER

TIMER

TEMP

ON/OFF

MODE

RESET

SWING

29

90

Two-way Valve

9.52mm(3/8")
12.7mm(1/2")

Liquid Side
6.35mm(1/4")

Gas Side

Mouth Nut
Three-way Valve

Open

Piping Connection for Outdoor Unit

Connect the Piping and Inlet and Outlet Liquid Tubes
Gas Drainage Method:
Drain the air in the indoor unit and the pipes as per the drawing:
(1) Remove the valve cap on the two-way valve of the indoor unit with a spanner.
(2) Unscrew by 1/2 cycle the nut on the mouth of the thick pipe connected with the three-way valve

with a spanner.

(3) Unscrew the spool of the two-way valve by 90 with an inner hexagon spanner, and after about 10

seconds,close the two-way valve,then air will be drained out from the mouth of the thick pipe. When
the air is drained out, screw tightly the nut on the mouth according to there quired torque.

(4) Open the two-way valve and three-way valve with an inner hexagon spanner.
(5) Check the leakage with soap liquid or a leakage checker.
(6) Screw tightly the two valve caps according to the required torque.

o

Notes: When the pipe is extended, the air in the connection pipe shall be drained out with

the

refrigerant(R22) from outside the system, then the excess refrigerant shall be drained out as per the air
drainage method.

Check the Layout of the Drain Pipe and Connection Wires
The drain pipe should be placed underneath, and the connection
wires should be plac

upside; and the drain pipe especially the

section inside the machine and indoors must be wound up with
insulating material to preserve heat

ed

The drain pipe shall be sloped and no concave and convex shall
occur along the whole pipe. And the cases as the right drawing
indicates shall not occur.

Specif.

Valve Spool
Valve Cap

Pipe Length
Refrigerant filled

5m
none

7m
32g

10m
80g

15m
160g

7-9
20-25

Torque

Tight screw N. M

Required Torque

When the connection pipe is more than 5 cm, it shall be filled with refrigerant as per the following
form:

Correct

Up-bent

End in the Water

Ripple

Bad Smell in the Pool

Prohibited

Prohibited

Prohibited

Prohibited

Installation