6. volt-ampere curves – Hobart Welding Products ARCSTAR OM-486 User Manual

Page 16

Advertising
background image

OM-486 Page 12

ST-189 266 / ST-189 267 / ST-189 265

The volt-ampere curves show the
minimum and maximum voltage
and amperage output capabilities of
the welding generator. Curves of
other settings fall between the
curves shown.

A. CC/DC Mode

B. CV/DC Mode

C. CC/AC Mode

3-6.

Volt-Ampere Curves

0

0

DC AMPERES

DC VOL

T

S

50

100

150

200

250

300

350

20

40

80

60

10

30

50

70

MAX

MIN

0

0

DC AMPERES

DC VOL

T

S

100

200

300

400

500

600

20

40

10

30

50

MAX

MIN

0

0

AC AMPERES

AC VOL

T

S

50

100

150

200

250

300

350

20

40

80

60

10

30

50

70

MAX

MIN

Advertising