Hobart Welding Products 150 STI User Manual

Page 13

Advertising
background image

OM-951 Page 11

1

Welding Power Source

Shoulder Strap

Use strap to lift unit.
2

Rating Label

Label is located on bottom of unit.

Use rating label to determine input

power needs.
3

Input Power Cord

4

115 or 230 VAC Grounded

Receptacle

.

The Auto-Line circuitry in this

unit automatically links the

power source to the primary

voltage being applied, either

115 or 230 VAC.

An individual branch circuit capable

of carrying 30 amperes and pro-

tected by fuses or circuit breaker is

recommended. Recommended

fuse or circuit breaker size is 30

amperes.
Y Unit is supplied with a 115

VAC plug. For 230 VAC op-

eration, have a qualified per-

son obtain a proper plug that

meets all applicable codes,

and install the plug accord-

ing to the manufacturer’s in-

structions.

Connect input power plug to proper

receptacle.
Y Special installation may be

required where gasoline or

volatile liquids are present −

see NEC Article 511 or CEC

Section 20.

Ref. 803 351-D / 218 322-A

3

4-4. Installing Shoulder Strap, Selecting A Location, And Connecting Input Power

18 in

(460 mm)

18 in

(460 mm)

Airflow Distance

Requirements

Y Do not move or operate unit

where it could tip.

2

1

Front Panel

To Rear Panel

4

EVIDENCE OF LABEL TAMPERING VOIDS WARRANTY

PROTECTED BY ONE OR MORE OF THE

FOLLOWING US. PATENTS:

(X,XXX,XXX)

(X,XXX,XXX)

(X,XXX,XXX)

(X,XXX,XXX)

(X,XXX,XXX)

(X,XXX,XXX)

(X,XXX,XXX)

(X,XXX,XXX)

(X,XXX,XXX)

(X,XXX,XXX)

(X,XXX,XXX)

(X,XXX,XXX)

(X,XXX,XXX)

(X,XXX,XXX)

(X,XXX,XXX)

(X,XXX,XXX)

(BAR CODE)

(SERIAL NUMBER)

XXXXXXXX

1

f2

30%

30%

X
I2

U2

100%

60%

150

150

100

120

16

16

14

14.8

X
I2

U2

35%

30%

100%

60%

100

150

70

85

24

26

22.8

23.4

18

28

13

23

Hz

50/60

1

100%

60%

120

100

14.8

14

100%

60%

120

100

24.8

24

5A/20V

150A/26V

5A/10V

150A/16V

Hobart
Appleton, WI USA

Hobart 150 (XXX)

S/N: (XXXXXXXXXX)

(XXXXXXXXXXXXX)

IP 23

For Help (XXXXXXXXXXXXXX)

U

1

=115V

U

1

=230V

U

0

=90V

U

0

=90V

U

1

=115V

U

1

=230V

I

1

=max

I

1

=eff

U

1

=115V

U

1

=230V

4-5.

Selecting Extension Cord (Use Shortest Cord Possible)

Single Phase AC

Conductor Size − AWG [mm

2

]*

Single Phase AC

Input Voltage

4 [21.2]

6 [13.3]

8 [8.4]

10 [5.3]

12 [3.3]

Input Voltage

Maximum Allowable Cord Length in ft (m)

115

160 (49)

107 (33)

71 (22)

47 (14)

29 (9)

230

471 (144)

321 (98)

215 (66)

146 (45)

90 (27)

*Conductor size is based on maximum 3% voltage drop

Advertising